40 breaths per minute and 0.65 breaths per minute, limits of agreement of -2.86 to 3.67 breaths per minute and -2.11 to 3.41 breaths per minute, respectively. The mean measurement time for "RRate" was 22.8s (95% CI 13.9-36.6), which was significantly shorter than the 65.8s (95% CI 61.0-73.2) for the measurement over 1 min (p .001). Respiratory rate can be measured accurately in a shorter time using a mobile phone application in adult patients. Respiratory rate can be measured accurately in a shorter time