Translate   10 w

https://www.selleckchem.com/pr....oducts/pifithrin-u.h
80(femur), 50(tibia), and 120(femur with tibia). Complications included broken implant, screw back out, screw irritation and rebound phenomenon. Conclusions 2-holed reconstruction plate gives similar correction to that of the 8-plate within a comparable period without additional complications. It has the advantage of being cost effective and readily available. Age, BMI, type of deformity, amount of initial deformity, do not play a significant role in the outcome of correction. Screw placement may have a role in the final correction

  • Like
  • Love
  • HaHa
  • WoW
  • Sad
  • Angry