This did not occur in the locking pin cap group. The locking pin cap construct group was able to sustain a significantly higher load compared with the industry standard when the construct was displaced to the 2-mm gap. The locking pin cap also significantly increased the ultimate load to failure compared with the industry standard. The novel locking pin cap creates a fixed-angle attachment of a K-wire to an existing locking screw hole in a plate. This fixed-angle K-wire is significantly stronger in preventing gap formation and resisting