https://www.selleckchem.com/products/cd532.html
To evaluate the technique of peripheral vitreous shaving during vitrectomy, we measured the residual peripheral vitreous using intraoperative optical coherence tomography (iOCT). This retrospective study included 44 eyes that underwent 25-gauge pars plana vitrectomy with iOCT by a single surgeon. In all cases, the surgery was performed via ocular indentation. Cases in group A were treated with vitreous shaving under slit lamp microscope illumination, whereas cases in group B were treated with vitreous shaving under a wide-angle viewing sy