https://www.selleckchem.com/products/ars-1620.html
Percutaneous mechanical thrombectomy devices have revolutionized the treatment of massive pulmonary embolism (PE) by providing a rapid, non-thrombolytic based method to re-establish right-sided circulation while reducing bleeding complications. However, with massive PE, the acute increase in right ventricular afterload results in a compounded hemodynamic compromise, which may necessitate the need for advanced cardiac support. This case exemplifies the need for a comprehensive and synergistic approach to the management of massive PE. To